Conventional (SUO601) | |
![]() |
The Tyco Manual Call Point (MCP) is a surface mounting call point with a plastic coated glass element to ensure reliable, safe operation. The Tyco MCP’s are available coloured Red or White. Note that for Red coloured devices, it is necessary to order both the MCP and the Wall Box. |
SU0600 15V Manual Call Point | |
![]() |
The SU0600 15V Manual Call Point (MCP) clamps the line voltage to 15 volts when actuated. When used on the same circuit as collective fire detectors, it complies with AS1670.1 by not extinguishing the LED indicator of an already activated fire detector. This MCP has a plastic coated frangible element to ensure safe and reliable operation, producing no dangerous glass shards. The MCP is operated by simply pressing on the centre of the frangible element until it snaps. This releases the MCP’s micro switch, which signals an alarm at the FIP and illuminates the integral LED indicator. The unit features IN and OUT terminals, which are requirements of AS1670.1 and is compatible with the MX4428 ADR-M, F3200 (band 3 Instant Alarm) and F08 version 3. Specifications
Part Numbers
*Max. current must be externally limited |
SU0631 Manual Call Point | |
![]() |
The SU0631 Manual Call Point is supplied with one normally open and one normally closed contact. Selecting either the “Normally Open” or “Normally Closed” contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP. Single pole changeover switching can be achieved with the use of two terminal blocks. The Call Point and Backbox are ordered separately. The call point is operated when the frangible glass element is snapped, releasing the MCP’s micro switch, which signals an alarm to the fire panel. Specifications
Part Numbers
|
4099-9032 Manual Call Point | |
![]() |
The 4099-9032 addressable Manual Call Point (MCP) provides a means to manually initiate a fire alarm condition to the 4100U c.i.e. via the IDNet channel. The IDNet channel provides the communication link and power between the call point and 4100U. Activation of the MCP requires the frangible element to be broken, which causes contacts on a microswitch to close, initiating an alarm condition. Call Point reset requires the fitting of a replacement frangible element. The MCP features an integral red LED status indicator. The Simplex 4099-9032NL MCP is connected to Simplex c.i.e. via MAPNET II and does not have a status indicator. Specifications
Part Numbers
1. MAPNET II or IDNet communications with data |
SU0608 Evacuation Manual Call Point | |
![]() |
The SU0608 MCP is surface mounting, with a plastic coated glass element to ensure reliable, safe operation. It is coloured white (for EWIS applications) to be used where a fire alarm system does not exist. The call point is operated when the glass element is snapped, releasing the MCP’s micro switch, which signals an alarm to the EWIS panel. The element is snapped by pressing on its centre – a hammer, or other impact device, is not required. Specifications
Part Numbers
|
SU0611 Waterproof Callpoint | |
![]() |
This surface mounting Manual Call Point has a plastic coated frangible element to ensure safe and reliable operation, producing no dangerous glass shards. The SU0611 is an IP67 rated MCP wih a single pole changeover switch configuration. SU0611 is operated by simply pressing on the centre of the frangible element until it snaps. A hammer, or other impact device, is not required. The snapped frangible element releases a microswitch, which signals an alarm at the CIE. It carries LPCB approval. Specifications
Part Numbers
|
SU0612 Rainproof Callpoint | |
![]() |
This surface mounting Manual Call Point has a plastic coated frangible element to ensure safe and reliable operation, producing no dangerous glass shards. The callpoint is operated by simply pressing on the centre of the frangible element until it snaps. A hammer, or other impact device, is not required. The snapped frangible element releases a microswitch, which signals an alarm at the CIE. The SU0612 provides IP55 protection for the terminal enclosure and IP55 for the switch. Ex rated devices are available. Contact TSP. Specifications
Part Numbers
|
Weather STOPPER | |
![]() ![]() |
The callpoint STOPPER provides protection from malicious or accidental activation of manual callpoints. Available for flush or surface mounted callpoints the ‘STOPPER’ is also available with optional high pitch sounder which is activated when the lid is lifted. An optional ‘Break-Seal’ fitting kit allows ‘Break-Seals’ to be used to provide extra protection. Specifications
Part Numbers
|
Weather STOPPER II | |
![]() |
The Weather STOPPER II extends the life of weather exposed callpoints, by offering protection against harsh conditions and environments, eg, oil rigs and ship decks. While offering environmental protection the Weather STOPPER II are constructed from polycarbonate which will also guard against tampering or accidental operation of devices. |
Manual Call Point Ancillaries | |
![]() |